Home / News / Industry News / How to maintain the correct zero-point when using stainless steel calipers to avoid measurement errors?

How to maintain the correct zero-point when using stainless steel calipers to avoid measurement errors?

26 Feb Industry News

Dirt, oil, or even minute debris can significantly affect the accuracy of a stainless steel caliper, particularly when measuring fine tolerances. Any foreign material present on the measuring surfaces may cause the jaws to fail to close evenly, leading to misaligned zero points and inaccurate measurements. Before use, it is essential to thoroughly clean the caliper, especially the measuring faces and sliding surfaces. Use a soft, lint-free cloth to wipe off any contaminants, and if necessary, employ a mild cleaning solution designed for metal tools. This ensures that the surfaces are free of oils or dirt that could alter the caliper's ability to measure precisely.

The calibration of a caliper is fundamental to maintaining measurement accuracy. Before taking any measurements, it is critical to check that the caliper is properly calibrated to zero. For digital models, ensure that the display reads zero when the jaws are fully closed, and for analog models, verify that the dial or scale aligns at zero. Any deviation from the zero-point before use can result in measurement errors. If the caliper shows any deviation from zero, recalibrate it immediately. Some digital calipers offer automatic calibration features, while manual calipers may require physical adjustment or use of a known reference point to reset the zero.

Using excessive force when closing the caliper jaws can distort the zero-point or introduce measurement inaccuracies. It’s important to apply only light, even pressure to avoid putting undue stress on the caliper’s mechanical components, which could cause them to misalign. Over-tightening or forcing the caliper to close when measuring an object can shift the internal mechanism, leading to misreadings. Always allow the caliper to naturally engage with the object being measured, ensuring the jaws make consistent, even contact with the measurement surfaces. This practice minimizes the risk of inadvertently altering the zero-point or damaging the tool.

Regularly zeroing the caliper is essential to maintain accuracy, especially after frequent use. Even if the caliper shows zero at the start of a session, it is good practice to check the zero-point periodically throughout measurement tasks. For digital calipers, this can be done easily by pressing the reset or zero button after each measurement or when switching between different sizes. For analog calipers, zeroing is done by adjusting the dial or scale to ensure it reads exactly zero when the jaws are fully closed. Performing this check prevents any drift from accumulating and ensures that subsequent measurements are accurate.

Storing the caliper in a manner that protects it from environmental damage is a critical aspect of maintaining its accuracy. When not in use, always store the caliper in its designated protective case, especially if it is a high-precision instrument. Improper storage can expose the caliper to physical damage, corrosion, or misalignment, which may affect the zero-point. Keep the measuring surfaces free from contact with foreign objects that could scratch, dent, or distort the metal, as such damage could shift the zero-point over time. Avoid storing the caliper in high-humidity areas, as moisture can promote corrosion, particularly on the measuring faces.

Over time, especially with frequent use in demanding environments, mechanical components such as the sliding mechanism, jaws, and locks of a caliper may experience wear and tear. This wear can lead to misalignment or a gradual shift in the zero-point, resulting in inaccurate measurements. Regularly inspect the caliper for signs of mechanical degradation, such as resistance in the sliding action, looseness in the locking mechanism, or visible wear on the measuring faces. If any of these issues are observed, the caliper should be recalibrated or serviced to restore its accuracy. In some cases, component replacement may be necessary to ensure continued precise measurements.